Adjusting Adf Magnification; Adjusting Scanner Registration - Lexmark X925 Service Manual

Hide thumbs Also See for X925:
Table of Contents

Advertisement

7541-03x

Adjusting ADF magnification

1.
Enter the Diagnostic menu: press and hold 3 and 6, turn on the printer, and release the buttons when the
splash screen appears.
2.
To print a test page from the Diagnostic menu, navigate to:
REGISTRATION > Quick Test
3.
To copy the test page from the Diagnostic menu, navigate to:
SCANNER CALIBRATION > Copy Quick Test.
4.
Navigate to:
SCANNER TESTS > ADF Magnification.
5.
Compare the copy to the original test page, and then adjust the value of the ADF Magnification setting as
needed. If the bottom margin is too small, decrease the value. If the bottom margin is too large, increase
the value.
6.
Touch Submit to save your changes.
7.
To check the changes, reload the original test page, and then repeat the Copy Quick Test. Repeat the
steps as needed.
8.
Once the margins look correct, check the registration of the ADF.
Perform the Copy Quick Test, and then repeat the process if needed.

Adjusting scanner registration

Note: If the printer menus do not match the following instructions, then contact your next level of support.
1.
Enter the Configuration menu: press and hold 2 and 6, turn on the printer, and release the buttons when
the splash screen appears.
2.
Navigate to:
Scanner Manual Registration > Print Quick Test
3.
Adjust the flatbed:
a. Place the printed test page facedown on the flatbed scanner glass, and select Copy Quick Test.
b. Compare the copy to the original test page.
c. Select Flatbed, and adjust the left and top margins as needed.
d. Touch Submit to save your changes.
e. To check the changes, reload the original test page, and then repeat the Copy Quick Test. Repeat
the steps as needed.
4.
Adjust the ADF Front:
a. Place the latest test page face up in the ADF, and select Copy Quick Test.
b. Compare the copy to the original test page.
c. Select ADF Front, and adjust the horizontal adjust and top margins as needed.
d. Touch Submit to save your changes.
e. To check the changes, reload the original test page, and then repeat the Copy Quick Test. Repeat
the steps as needed.
5.
Adjust the ADF Back:
a. Place the latest test page facedown in the ADF, and select Copy Quick Test.
b. Compare the copy to the original test page.
c. Select ADF Back, and adjust the horizontal adjust and top margins as needed.
d. Touch Submit to save your changes.
e. To check the changes, reload the original test page, and then repeat the Copy Quick Test. Repeat
the steps as needed.
Touch Back to return to the Configuration Menu.