Scanner calibration reset

This is test is run to reset the scanner calibration. This test should only be run after a flatbed or ADF unit has been
replaced.
To perform this operation, do the following:
1
Navigate to Scanner Tests.
2
Select Scanner Calibration Reset. This procedure should only be run after the scanner or
ADF has been replaced displays.
3
Ensure that the scanner glass and white flatbed cushion on the ADF are clean.
4
Select Continue. If the test is successful, then Operation completed successfully displays for three
seconds, and then returns to the main Scanner Calibration Reset menu. If an error occurs during the test, then
Test Failed, Please Retry displays, and a Continue button appears that takes you back to the main
Scanner Calibration Rest Menu screen.
5
Select Exit to leave the test
After successfully executing this test, verify the results.
1
Load the ADF with a document containing both light and dark content.
2
Perform a duplex copy. If the back side of the resulting copy contains vertical streaks, then the SE should clean the
scanner glass and backing sheet, execute the back side scan uniformity procedure, and then perform another copy.
If streaks still appear on the resulting copy, then the SE can repeat the cleaning and verification procedure a second
time or can replace the ADF entirely.

ADF magnification

This test allows the service technician to adjust the ADF magnification level. To adjust the ADF magnification level,
perform the following steps:
1
Navigate to Diagnostic menu>Scanner Tests>ADF magnification.
2
Use the plus or minus buttons to scroll through the magnification values. The values are 1.000, 1.005, 1.007, .980, .
985, .990 and .995.
3
Press the check button to accept the value. Press the X on the screen to exit the test.

Exit Diagnostics

Press Select to exit Diag Menu. The printer performs a power-on reset and returns to normal mode.

Configuration menu

"Entering configuration mode" on page 189
"Available tests" on page 189
"Action for prompts" on page 190
"ADF Edge Erase" on page 190
"Size sensing" on page 191
"Print Quality Pages" on page 191
Service menus
188
7527

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cx310dnCx410eCx510eCx410deCx510de

Table of Contents