Problem: Starter button not effective
Condition
1. Battery charge low
2. Switch contacts defective
3. Starter motor brushes not seating
4. Starter relay defective
5. Emergency stop - ignition switch off
6. Wiring connections loose - disconnected
Problem: Battery "sulfation" (Acidic white powdery substance or spots on surfaces of cell plates)
Condition
1. Charging rate too low - too high
2. Battery electrolyte insufficient
3. Specific gravity too low
4. Battery run-down - damaged
5. Electrolyte contaminated
Problem: Battery discharges too rapidly
Condition
1. Electrolyte contaminated
2. Specific gravity too low
3. Charging system not charging
4. Cell plates overcharged - damaged
5. Battery short-circuited
6. Specific gravity too low
Problem: Battery polarity reversed
Condition
1. Battery incorrectly connected
Back
5-14
Back to TOC
Remedy
1. Charge - replace battery
2. Replace switch
3. Replace starter motor
4. Replace relay
5. Turn on switches
6. Connect - tighten - repair connections
Remedy
1. Replace battery
2. Keep electrolyte to prescribed level
3. Charge battery - add distilled water
4. Replace battery
5. Replace battery
Remedy
1. Replace battery
2. Charge battery - add distilled water
3. Check magneto - regulator/rectifier - circuit connections
4. Replace battery - correct charging system
5. Replace battery
6. Charge battery
Remedy
1. Reverse connections - replace battery - repair damage