SIP User's Manual
Parameter
Single IP Network Parameters
Web: IP Address
EMS: Local IP Address
[LocalOAMIPAddress]
Web: Subnet Mask
EMS: OAM Subnet Mask
[LocalOAMSubnetMask]
Web: Default Gateway Address
EMS: Local Def GW
[LocalOAMDefaultGW]
VLAN Parameters
Web/EMS: VLAN Mode
[VLANMode]
Version 5.8
is required.
Each interface index must be unique.
Each IP interface must have a unique subnet.
Subnets in different interfaces must not be overlapping in
any way (e.g., defining two interfaces with 10.0.0.1/8 and
10.50.10.1/24 is invalid). Each interface must have its own
address space.
Upon device start up, this table is parsed and passes
comprehensive validation tests. If any errors occur during
this validation phase, the device sends an error message to
the Syslog server and falls back to a "safe mode", using a
single IPv4 interface and without VLANs. Therefore, check
the Syslog for any error messages.
When booting using BootP/DHCP protocols, an IP address
is obtained from the server. This address is used as the
OAMP address for this session, overriding the address
configured using the InterfaceTable. The address specified
for OAMP applications in this becomes available when
booting from flash again. This enables the device to work
with a temporary address for initial management and
configuration while retaining the address to be used for
deployment.
For configuring additional routing rules for other interfaces,
use the 'Tel to IP Routing' table.
To configure multiple IP interfaces in the Web interface and
for a detailed description of the table's parameters, refer to
''Configuring the Multiple Interface Table'' on page 63).
For a description of configuring ini file table parameters,
refer to ''Format of ini File Table Parameters'' on page 219.
The device's source IP address in the operations,
administration, maintenance, and provisioning (OAMP)
network.
The default value is 0.0.0.0.
Note: For this parameter to take effect, a device reset is
required.
The device's subnet mask in the OAMP network.
The default subnet mask is 0.0.0.0.
Note: For this parameter to take effect, a device reset is
required.
N/A. Use the IP Routing table instead.
Enables the VLAN functionality.
[0] Disable (default).
[1] Enable = VLAN tagging (IEEE 802.1Q) is enabled.
Notes: