DIMM names in appliance logs and the Maintenance > Hardware view are displayed with the
full name, such as /SYS/MB/P0/D7.
Fan Modules
The Fan Modules and Fan Module LEDs of the controller are shown in the following figure. The
following LEDs are lit when a fan module fault is detected:
Front and rear Service Action Required LEDs
■
Fan Module Service Action Required (TOP) LED on the front of the server
■
Fan Fault LED on or adjacent to the faulty fan module
■
The system Overtemp LED might light if a fan fault causes an increase in system operating
temperature.
NIC/HBA Options
This table describes NIC/HBA PCIe card options for ZS3-4 standalone and cluster
configurations.
Mktg Part Number
Description
SG-SAS6-INT-Z
8-port 6Gb/s SAS-2 internal HBA
SG-XPCIE2FC-QF8-Z 2-port, 8Gb FC HBA
7103791
4-port (4x4 SAS-2) 6Gb/s external
HBA
7100477
4-port 1Gb Ethernet Copper UTP
Chapter 1 • Introduction
ZS3-4
31