The baud rate of the console port is 19,200 bps.
The screen can contain up to 30 lines.
The history command buffer can contain up to 20 commands.
The timeout time of the AUX user interface is 6 minutes.
2)
Network diagram
Figure 2-5 Network diagram for AUX user interface configuration (with the authentication mode bein
none)
3)
Configuration procedure
# Enter system view.
<Sysname> system-view
# Enter AUX user interface view.
[Sysname] user-interface aux 0
# Specify not to authenticate users logging in through the console port.
[Sysname-ui-aux0] authentication-mode none
# Specify commands of level 2 are available to users logging in to the AUX user interface.
[Sysname-ui-aux0] user privilege level 2
# Set the baud rate of the console port to 19,200 bps.
[Sysname-ui-aux0] speed 19200
# Set the maximum number of lines the screen can contain to 30.
[Sysname-ui-aux0] screen-length 30
# Set the maximum number of commands the history command buffer can store to 20.
[Sysname-ui-aux0] history-command max-size 20
# Set the timeout time of the AUX user interface to 6 minutes.
[Sysname-ui-aux0] idle-timeout 6
After the above configuration, you need to modify the configuration of the terminal emulation utility
running on the PC accordingly in the dialog box shown in

Console Port Login Configuration with Authentication Mode Being Password

Configuration Procedure
Follow these steps to configure console port login with the authentication mode being password:
Figure 2-4
to log in to the switch successfully.