4.Power off relay
.Remove the relay from cable
.Connect portable multitester (¦¸¡Á1)and battery (12V)
to wire end of power off relay
Battery end(+)¡úred/white wire end ¢Ù
Battery end(-)¡úgreen/yellow wire end ¢Ú
Multitester pen(+)¡úred/white wire end ¢Ù
Multitester pen(-)¡úblue/white wire end ¢Û
.Inspect if the power off relay is on
5.Starting relay
.Remove the connector of starting relay from cable
.Connect the multimeter (¦¸¡Á1)and battery (12V)to
terminal of power off relay.
Battery wire end(+)¡úblue/white wire end ¢Ù
Battery wire end(-)¡úblack wire direction ¢Ú
Multitester pen(+)¡úred white end ¢Û
Multitester pen(-)¡úblack wire end ¢Ü
-124-
The circuit is on
The circuit is on
No rotation
Repair or replace starting motor
Replace power off relay
The circuit is not on
Replace starting off relay