Section 5: Parts and Module Replacement
5.2
GENERAL SAFETY WARNINGS AND GUIDELINES
5.3
REPLACEMENT PROCEDURES
5.3.1 Tools Required
• Keys for security locks (includes Low and High Security Keys)
• Convergence Tool Set
• Long and stubby neck magnetic-tip Phillips
• Hex keys: 3mm, 5mm
• Nut driver: 7mm
• Ratchet: 17mm
• Electrostatic protective strap and pad
• Disposable Nitrile gloves (included with optical components)
• Protective clothing/safety gear (required when handling lamp), includes:
• face shield
• vinyl-coated or interlock knit-lined gloves
• nylon flak jacket
5.3.2 Servicing Guidelines
• Always power down and disengage all power sources to the projector prior to servicing.
• Follow all service safety guidelines.
• Refer to
Section Appendix A: Exploded Views
• When re-installing a module, follow the removal instructions in reverse unless otherwise indicated.
• Refer to
Section 6 Interconnections
5-4
HIGH VOLTAGES! Always power down and disconnect power sources prior to
servicing. All module replacement procedures must be performed by Christie
authorized service technicians. Once the projector is powered down, allow the
cooling fans to automatically turn OFF before disconnecting from AC and
opening the projector. This takes approximately 10 minutes.
Use a grounded wrist strap when handling electronic assemblies.
when re-connecting harnesses.
screwdrivers - #1, #2
™
for the location of serviceable modules.
D4K35 Service Manual
020-100817-01 Rev. 1 (04-2012)