Performance specifications are based on information available at the time of printing. Christie makes no warranty of any kind with regard to this material, including, but not limited to, implied warranties of fitness for a particular purpose.
Page 5
Addendum Translated copies of this document are provided on the CD in the back of this document. The CD may also contain additional product documentation. Read all instructions before using or servicing this product. 本文档的翻译副本在本文档背面的 CD 上提供。该 CD 中还可能包含其他产品文档。使用或维修本产 品之前请务必阅读所有说明。 文件背面的光碟提供了本文件的翻譯副本。這張光碟可能另外包含其他產品文件。請先閱讀所有指 示再使用或送修本產品。 Le CD au dos de ce document contient des traductions de celui‐ci dans différentes langues. Ce CD peut également contenir de la documentation supplémentaire sur le produit. Lisez toutes les instructions avant d'utiliser ou d'entretenir ce produit. Übersetzte Versionen dieses Dokuments werden auf der CD auf dem Vorsatzblatt dieses Dokuments bereitgestellt. Die CD kann auch zusätzliche Produktdokumentation enthalten. Bitte lesen Sie diese Anweisungen vor der Verwendung dieses Produkts oder vor der Ausführung von Wartungsarbeiten am Produkt. Le copie tradotte di questo documento sono fornite sul CD, sul retro di questo documento. Il CD potrebbe anche contenere altra documentazione sul prodotto. Si prega di leggere tutte le istruzioni prima di utilizzare questo prodotto o sottoporlo a manutenzione. このドキュメントの翻訳版がこのドキュメントの裏面の CD で提供されています。CD には追加の 製品マニュアルも収められています。この製品を使用したり、機能させたりする前に、すべての 指示をお読みください。 이 문서의 번역된 사본이 이 문서 후면의 CD 에서 제공됩니다 . 이 CD 에는 추가 제품 설명서가 포함되 어 있을 수 있습니다 . 이 제품을 사용하거나 수리하기 전에 모든 지침을 확인하십시오 . Copias traduzidas deste documento são fornecida no CD contido na parte de trás deste documento. O CD pode conter documentação adicional do produto. Leia todas as instruções antes de usar ou prestar serviço com este produto.
Safety and Warning Guidelines This projector must be operated in an environment that meets the operating range specification. Use only the attachments and/or accessories recommended by Christie. Use of others may result in the risk of fire, shock or personal injury.
• Verify that the projector is using a line cord, socket and power plug that meets the appropriate local rating standards. Use only an AC power cord recommended by Christie. Do not attempt operation if the AC supply and cord are not within the specified voltage and power range.
Indicates exposure to bright light. To avoid personal injury, do not look directly at the light source. Indicates the presence of an explosion hazard. To avoid personal injury, always disconnect all power sources and wear Christie approved protective clothing. Indicates the presence of a fire hazard. To avoid personal injury and property damage, always adhere to the instructions described in this manual.
The D4K2560 offers stunning wide screen, high-resolution 4K images at 60 frames per second. Contact Your Dealer If you encounter a problem with your Christie projector, contact your dealer. To assist with the servicing of your projector, enter the information in the tables below and keep this information with your records.
Choice of field-interchangeable zoom lenses How the Projector Works The D4K2560 accepts a variety of input signals for projection on front or rear projection screens, typical in commercial or other large screen applications. High-brightness light is generated by a short arc Xenon lamp, then modulated by 3 Digital Micromirror Device (DMD) panels responding to incoming data streams of digitized red, green and blue color information.
Installation and Setup This section explains how to install, connect and optimize the projector display. Site Requirements To safely install and operate the D4K2560 projector, the installation location must meet these minimum requirements: Physical Operating Environment • Maximum Ambient Temperature (operating) 35°C (95°F) •...
42. Shroud (2-piece) Covers the motorized lens mount assembly. Projection Lens A variety of lenses can be used with the D4K2560. For a list of available lenses, see Accessories on page 60 Air Filter Cover and Air Filter Filters the intake air before it circulates through the front compartment to cool the main electronics.
• Keep the projector level when lifting or transporting. Avoid tilting the projector to the right. This can introduce an air bubble into the coolant hoses that can result in an air lock and the overheating of the projector. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
If using an optional rack stand (P/N: 108-282101-02), assemble the rack stand using the instructions provided with the rack stand. Use the hold down clamp (P/N: 116-100101-01) when securing the projector to the rack stand. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
2. Remove 4 screws securing the knockout plate to the bottom right corner of the front bezel. Remove the knockout plate. The AC supply is routed to the terminal block through an appropriate strain relief mounted on this knockout plate. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
Page 22
4. Reinstall the knockout plate and secure it with 4 screws. 5. Reinstall the bottom access panel over the terminal block and secure it with 2 screws. 6. If using a pluggable type-B cable, connect to the building’s AC power source. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
Failure to comply could result in death or serious injury. The D4K2560 lens should be centered and parallel with the screen. This orientation ensures ideal lens performance with minimal offset. If this position is not possible (such as when the projector is significantly higher than the center of the screen), it is better to rely on offset rather than extra tilt.
3,000 feet (914.4 m), when measured at the projector exhaust opening. To determine the projector exhaust CFM value, use an airflow meter to measure the ft/min at the rigid end of the open D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
1. Use finger pressure to push down on the shroud clips, as shown by the red arrows. 2. Carefully slide the shroud sideways and forward away from the lens mount and lens, as shown by the black arrows. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
Make sure those within the vicinity of the projector are also wearing protective safety clothing. Never twist or bend the quartz lamp body. Use the correct wattage lamp supplied by Christie. Failure to comply results in death or serious injury.
MCPU faceplate The GPIO connector is for future use. This section provides information and procedures for connecting external devices to the D4K2560 projector. Communication and input ports are located on the projector side input panel, accessed by removing the input panel cover.
For applications or equipment utilizing serial communications, use the Christie-proprietary serial protocol to communicate with the RS-422 port or the RS-232 ports on the MCPU faceplate. The RS-232 port located on the MCPU faceplate utilizes Christie-proprietary protocol and is intended for Christie accessories or automation controllers only.
2. Set the network information for the projector: • To obtain information automatically from the network, tap Automatic. • To manually enter the network information, tap Manual and enter the IP Address, Subnet Mask and Gateway (optional). 3. Click Ok. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
This section provides information and procedures for adjusting the projector image. Screen Image Orientation The D4K2560 provides support for front projection, rear projection, front projection inverted and rear projection inverted. 1. Tap Menu Tab > Configuration > Screen Image Orientation.
8. Tighten the lock screw (A) and the lens mount stabilization screw (D) to maintain the adjustments. 9. Check the boresight again. 10. Unless proceeding to adjust vertical boresight, perform a lens calibration as described in Calibrate the Lens Motors on page 48 D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
Normally, the three colors should overlap precisely to form pure white lines throughout the image and one or more poorly converged individual colors may appear adjacent to some or all of the lines. Contact your Christie accredited service technician to correct DMD convergence issues.
Adjust the Image Color Correction The D4K2560 provides automatic and custom color adjustments via the Color Correction menu. The available color adjustment controls are listed in the table below: Menu Description Max Drives All color adjustments are turned off allowing the projector to run at maximum brightness.
2. Adjust the fold mirror: • Adjust the screw on the lens side to raise or lower the image. • Adjust the screw on the lamp side to move the image left or right. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
1. Tap the Home tab. 2. Tap the Power button. NOTE: When powering Off in preparation for inspection or maintenance, always disconnect from AC and set the projector breaker to the Off position. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
7. Repeat steps 5 to 6, but take the readings at the screen instead of at the lens. View Lamp Information To view a history of all previously installed lamps, tap Menu Tab > Lamp > Lamp History. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
The projector uses pre-configured channels to determine how to display images from different sources. Each channel file contains the optimum processing and display settings for the source. Channels can be created or selected through the Home tab on Touch Pad Controller (TPC). D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
USB port that can be used to download log files and install software upgrades. For remote applications, the TPC can be disconnected from the projector utilizing the optional cable to allow projector control from a maximum distance of 100 ft (30 m). D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
• Ethernet Settings - See Ethernet Setup on page 22. • Color Correction - See Color Correction on page 28. • Calibrate Lens Motors - See Calibrate the Lens Motors on page 36. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
Use this menu to display the operating temperatures as reported by the internal thermal sensors. Versions Use this window to display the hardware and software versions for all electrical components, such as: main control board, backplane, image processor, formatter boards and option cards. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
2. Wrap a lens tissue around a swab and soak it in lens cleaning solution. The tissue should be damp but not dripping. 3. Gently wipe the surface using a figure eight motion. Repeat until the blemish is removed. Clean the lens only if absolutely required. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
After the lens motors are physically moved using the manual adjustment knobs. • After the projector is moved and/or jostled. • After the lens motor IMCB has been replaced. To calibrate the lens motors, tap Menu Tab > Configuration > Calibrate Lens Motors. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
Troubleshooting This section provides information and procedures for resolving common projector issues. If a projector issue cannot be resolved, contact a Christie accredited service technician. Projector Does Not Power ON • Make sure the projector circuit breaker is set to the ON position.
Increase the lamp power. Lamps which are near end of service may not operate reliably at a lower power setting. • Fold mirror misalignment. Contact your Christie accredited service technician. • Integrator rod misalignment. Contact your Christie accredited service technician.
Verify the projector is level and the lens surface and screen are parallel to one another. • Adjust the vertical offset of the lens mount. • Integrator rod misalignment. Contact your Christie accredited service technician. Display has Suddenly Frozen • If the source is frozen, restart the source device.
Specification This section provides detailed D4K2560 specifications. Due to continuing research, specifications are subject to change without notice. Display Panel Resolution and Refresh Rate Pixel format (H x V square pixels) 4096 x 2160 Processing path 23.97 - 60Hz Achievable Brightness (Measured at Screen Center) Nominal 2.0 kW (CDXL-20)
Quad Link DVI Vertical Name Format (Pixels) Frequency (HZ) Timing Quad HDTV 3840 x 2160 CVT-RB Quad HDTV 3840 x 2160 CVT-RB Quad 2K 4096 x 2160 CVT-RB Quad 2K 4096 x 2160 CVT-RB D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
1 start bit, 8 data bits, 1 stop bit, no parity RS-232 OUT Connector 9-pin subminiature D, male Bit Rate 115,200 bps Data Format 1 start bit, 8 data bits, 1 stop bit, no parity D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
NOTE: Projectors typically force a 10 minute cool down period. Make sure not to re-strike the lamp any sooner than 2 minutes into this cool down period since hot re-strikes reduce lamp life. D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
Zealand, Kuwait, China, Korea, Japan, Mexico, Ukraine, Russia, South Africa, and Saudi Arabia international packaging recycling mark requirements: • EU Directive (94/62/EC) on packaging and packaging waste; • China packaging recycling mark standard (GB18455-2001). D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)
10 to 35°C (50 to 95°F) Humidity (non-condensing) 20 to 80% Altitude 0 to 3000 meters Maximum ambient temperature 35°C Non-Operating Environment Temperature -25 to 65°C (-13 to 149°F) Humidity (non-condensing) 0 to 95% D4K2560 User Manual 020-101076-01 Rev. 1 (06-2013)