Lamp ID (Type) (LID)
Get lamp type (ID) for the currently installed lamp. Supports readback of the list of supported lamp types.
SUBCODE
DESCRIPTION OF USE
Get Lamp ID for current lamp. This is a read-only control. Lamp ID can be changed with LPC (lamp
NONE
change) command only.
EXAMPLES:
(LID?L) List supported lamp IDs
(LID?) Get the lamp ID for installed lamp
LampLOC™ Module (LLM)
Allows adjustment of lamp position to optimize intensity and uniformity of the optical system. This is referred to
as the LampLOC™ feature and can be done automatically or manually.
SUBCODE
DESCRIPTION OF USE
Set to 1 to do LampLOC™ automatically. It will do calibration first, then move the X, Y, Z-motors to find
AUTO
the maximum brightness. Set to 0 to cancel auto adjustment and restore the previous position. Reset to 0
when it has finished.
Calibrate LampLOC motors.
CALI
Moving X-axis motor manually. Data range from ±250.
MTRX
Moving Y-axis motor manually. Data range from ±250.
MTRY
Moving Z-axis motor manually. Data range from ±175.
MTRZ
Not Available
NONE
Provides feedback (status) on the progress of the Auto mode. Read-only command. Data range from 0 to
STAT
100, where 100 indicates the LampLOC™ is finished.
EXAMPLES:
(LLM+MTRX 100) Move motor X to position 100
(LLM+AUTO 1) Do LampLOC™ automatically
(LLM+AUTO 0) Abort LampLOC™. It will restore the motors to previous position automatically
(LLM+AUTO?) Get running status. (LLM+AUTO!000) indicates finished, (LLM+AUTO!001) indicates running
(LLM+STAT ?) Get the progress feedback of the Auto mode (0-100%)
Adjust All Lens Position Parameters Simultaneously (LMV)
Adjust all lens position parameters simultaneously.
SUBCODE
DESCRIPTION OF USE
(LMV <lho><lvo><zom><fcs><lhodir><lvodir><zomdir><fcsdir>)
NONE
where <lhodir>, <lvodir>, <zomdir>, and <fcsdir> represent the horizontal, vertical, zoom, and focus
position information. Valid values for direction are 1 and -1.
EXAMPLES:
(LMV 1000 1500 500 -500 -1 -1 1 1)
D4K35 Service Manual
020-100817-01 Rev. 1 (04-2012)
Section 7: Serial API
7-11