Physical Specifications; Regulatory; Safety; Electro-Magnetic Compatibility - Christie D4K35 Service Manual

Christie d4k35 4k resolution for superior 3-chip dlp displays
Hide thumbs Also See for D4K35:
Table of Contents

Advertisement

Section 8: Specifications
CDXL-601000 hours
Wait time between lamp strikes:
NOTE: Projectors typically force a 10 minute cool down period. Ensure you do not re-strike the lamp any
sooner than 2 minutes into this cool down period since hot re-strikes reduce lamp life.
Other lamps with bulb diameters not exceeding 70mm may also be used, however the projector may not meet
its specified light output rating. Such lamps include the following:
CXL-20(2.0kW Xenolite® bulb)
NOTE: CXL-20 lamp requires lamp adaptor kit listed below in Section 8.11.2 Accessories (sold sepa-
rately)
CXL-30(3.0kW Xenolite® bulb)
8.8

Physical Specifications

Overall Size (L x W x H):
(including lens mount, stack and feet)
Weight:
As installed with lens
Shipping (includes packaging)
Operating Position:
Rotation about projection axis± 15 degrees maximum
Tilt of projection axis from horizontal
8.9

Regulatory

This product conforms to the following regulations related to product safety, environmental requirements and
electromagnetic compatibility (EMC):

8.9.1 Safety

CAN/CSA C22.2 No. 60950-1-07, 2nd edition
UL 60950-1, 2nd Edition
IEC 60950-1:2005, 2nd Edition
EN60950:2006+A11:2009

8.9.2 Electro-Magnetic Compatibility

Emissions

FCC CFR47, Part 15, Subpart B, Class A - Unintentional Radiators
CISPR 22:2008-09/EN 55022:2006+A1:2007, Class A - Information Technology Equipment
8-8
2 minutes min.
1211 mm (47.7 inches) x 635 mm (25.0 inches) x 483 mm
(19.0 inches)
111 kg (245 lbs)
143 kg (315 lbs)
± 15 degrees maximum
D4K35 Service Manual
020-100817-01 Rev. 1 (04-2012)

Advertisement

Table of Contents
loading

Table of Contents