Replacing The Inline Check Valve - VKI Technologies Eccellenza Pod Service Manual

Hide thumbs Also See for Eccellenza Pod:
Table of Contents

Advertisement

Replacing Components
5. Secure the air pump to the opening on the metal wall using a large tie-wrap.
6. Connect the outlet hose to the air pump.
7. Test the machine to make certain everything is functioning properly.

Replacing the Inline Check Valve

The air pump is equipped with a check valve that prevents water from flowing into the
pump, but still allows air to flow out of the pump. To replace this check valve;
1. Cut the two tie-wraps on the check valve and pull the hose off each side. The
check valve has now been removed.
NOTE: The check valve must be installed in the proper direction or you risk
damaging it and/or other components in the equipment.
2. Connect the pump side tubing to the flat side of the check valve.
3. Connect the other tube to the tapered side of the check valve.
4. Secure the tubing with a tie-wrap on each side of the check valve.