Replacing Components
13. Insert the whipper chamber into the base (making sure to also insert the chamber's
inlet into the adaptor), and turn the handle on the locking ring to the center position
to secure the chamber.
14. Install the steam trap (vacuum cap) onto the whipper chamber.
15. Connect the inline wiring connector that supplies power to the whipper motor.
16. Install the whipper support plate onto the machine and secure it with four screws.
17. Connect the whipper outlet hose, and rotate the spout caps to open each of the
powder hopper spouts.
18. Close the front door and install the waste bin.
19. Power on the machine. A rinse cycle is now required.
20. Perform a "Powder Rinse" cycle to flush any powder that may have fallen into the
whipper chamber.
58
Eccellenza Pod

Hide quick links: