Disassembling An Outlet Valve - VKI Technologies Eccellenza Pod Service Manual

Hide thumbs Also See for Eccellenza Pod:
Table of Contents

Advertisement

Eccellenza Pod

Disassembling an Outlet Valve

O-Ring
Valve Body - Outlet
Valve Body - Main
1. Remove the breather tube from the valve.
2. Rotate the outlet section of the valve body counterclockwise to release it from the
main valve body, and pull the two sections apart. Be careful not to lose the small
orange o-ring located between the two valve body sections.
3. Remove the hex nut from the coil, and remove the coil from the main valve body. Be
careful not to lose the small black spacer located between the coil and main
valve body.
Overview of Outlet Valve Components
Breather Tube
Diaphragm
Plunger
Plunger Spring
Plunger Housing
Spacer
Replacing Components
Hex Nut & Washer
Coil
45