Air Pump

1. Remove the top and rear panels.
2. The air pump is located on the left of the wall behind the brewer (the water pump is
also located in this area, on the right side).
3. Cut the tie-wrap securing the air pump to the wall and disconnect the power wires
and the outlet hose from the pump.
4. Connect the power wires to the new air pump. Note that this is a DC powdered
pump and the wires must be placed on the correct terminals. Connect the
white wire (positive) to the terminal with the '+' marking, and connect the black wire
(ground) to the other terminal.
-
+