Replacing Components
Outlet Valve Manifold
1. Switch the machine power off and unplug the service cord.
2. Turn off the water supply, and drain the water tank.
3. Remove the rear panel and the top panel.
NOTE: The Eccellenza Pod machine is equipped with a dual outlet valve
manifold (two stacked outlet valves in one assembly - one for the powder
and one for hot water).
4. Disconnect the valve wiring and the valve outlet hoses. Be careful that the hoses do
not fall through their cutouts in the center wall.
5. Lift the water tank and pull the outlet valve manifold from the valve port on the
water tank. The tank must be lifted high enough so that the valve clears the side
wall. Use caution as there may still be a bit water remaining behind the valve
when you remove it – this water may be extremely hot.
42
Eccellenza Pod