Installation instructions

Environment
The router must be installed and used inside a building.
The ambient temperature must not exceed 45°C.
The router must not be exposed to direct strong sunlight nor to an intense heat source.
The router must not be placed in an environment subject to vapour condensation.
The router must not be exposed to water projections.
The router unit must not be covered.
Power source
Use a network socket with easy access, which is close to the equipment. The power cord is
2 m in length.
Arrange the power cord so as to prevent any accidental cutoff of the router.
The router is designed to be connected to a TT or TN type power network.
The router is not designed to be connected to an electrical installation with an IT type
diagram (neutral connected to earth through an impedance).
Protection against short circuits and inter-phase leakages, neutral and earth must be
ensured by the building's electrical installation. The power circuit of this equipment must be
fitted with a 16 A protection against power surges, and with a differential protection.
Maintenance
It is prohibited to open the case. Only qualified personnel approved by your supplier may do
so.
Do not use liquid or spray cleaning agents.
Sagemcom document. Reproduction and disclosure prohibited
2 - Description and connection of your router
F@st™ 2804v2 Reference Manual - 253329475-A
Page 2-11