Setting Up the System
When/How to Use
Related Parameters/Features
If Set Too High
If Set Too Low
Min
Channel Specific Parameters - #181
Duration of Ring
On (RINGON)
When/How to Use
Related Parameters/Features
If Set Too High
If Set Too Low
Min
Channel Specific Parameters - #182
Maximum
Answer Time
(MAXANSR)
When/How to Use
Related Parameters/Features
If Set Too High
If Set Too Low
Octel 50 Installation Guide
Max
Default
1
30000
5
Max
Default
1
30000
3
Configuring System Setup Parameters
For most Octel 50 systems, the default value is sufficient. If
your switch uses European-style rings, you may need to
adjust this setting. Call a technical support representative
for information on setting this parameter for European-style
rings.
None.
The Octel 50 system cannot detect rings and does not
answer incoming calls.
The Octel 50 system could misinterpret skips and jumps in
the ring voltage as incoming calls.
Requires
Restart
Dependent
Yes
This parameter specifies the amount of time, in 100
millisecond units, that ring voltage must be on for the Octel
50 system to identify a ring cycle.
For most Octel 50 systems, the default is sufficient. If your
phone system uses European-style rings, you may need to
adjust this setting. Call a technical support representative
for information on setting this parameter for European-style
rings.
None.
The Octel 50 system cannot detect rings and does not
answer incoming calls.
The Octel 50 system could misinterpret short instances of
line noise as incoming calls.
Requires
Restart
Dependent
Yes
This parameter specifies the maximum allowable time, in 10
millisecond units, for a greeting before returning a connect
signal. This parameter is used for outcall applications
(message delivery).
This parameter is useful for answering machines
applications, such as polling surveys.
Do not modify this parameter unless directed to change it by
a technical support representative.
None.
Should have no effect on system performance.
The system may assume a connect too soon.
Switch-
Set by
Integrator
Yes
No
Switch-
Set by
Integrator
Yes
No