Avaya Octel 50 Installation Manual page 127

Table of Contents

Advertisement

Setting Up the System
Message Waiting Light Parameters - #124
Light Message
Waiting Light for
Every Message
When/How to Use
Related Parameters/Features
If Set Too High
If Set Too Low
Min
Message Waiting Light Parameters - #125
Message Waiting
Light Dials
Number On Hook
When/How to Use
Related Parameters/Features
If Set Too High
If Set Too Low
Min
Octel 50 Installation Guide
Max
Default
No
Max
Default
No
Configuring System Setup Parameters
This parameter determines whether the Octel 50 system
sends a message waiting light request every time a
message is received.
This parameter is set when the Integrator is run for switches
that do not reliably schedule message waiting lights. Do not
change the setting of this parameter unless instructed to by
a technical support representative.
The Octel 50 system synchronizes message waiting light
events by sending one message waiting light activation
code to a port, then one message waiting light deactivation
code when the messages are retrieved by the subscriber. If
this parameter is enabled, message waiting light
synchronization is disrupted when a port has several
message waiting light activation codes for a mailbox, and
receives only one message waiting light deactivation code.
When this occurs, the remaining message waiting light stay
active, even though there are no more new messages, until
the port is manually reset.
Some switches limit the number of message indications per
phone. In this case, do not enable this parameter.
If this parameter is enabled, outbound ports that activate
and deactivate message waiting lights are tied up until the
port is manually reset.
Not applicable.
Not applicable.
Requires
Restart
Dependent
No
This parameter determines whether the phone system
remains on hook when the Octel 50 system sends the string
for message waiting light events.
This parameter is set when the Integrator utility is run for
Octel 50 systems using some SL-1 integrations. Do not
adjust this parameter unless instructed to by a technical
support representative.
None.
Not applicable.
Not applicable.
Requires
Restart
Dependent
No
Switch-
Set by
Integrator
Yes
Yes
Switch-
Set by
Integrator
Yes
Yes
8-67

Advertisement

Table of Contents
loading

Table of Contents