Avaya Octel 50 Installation Manual page 126

Table of Contents

Advertisement

Setting Up the System
Min
Message Waiting Light Parameters - #122
Message Waiting
Light Suffix OFF
Code
When/How to Use
Related Parameters/Features
If Set Too High
If Set Too Low
Min
Message Waiting Light Parameters - #123
Message Waiting
Light Supervised
When/How to Use
Related Parameters/Features
If Set Too High
If Set Too Low
Min
Octel 50 Installation Guide
Max
Default
0
32
Blank
Max
Default
0
15
Blank
Max
Default
No
Configuring System Setup Parameters
Requires
Restart
Dependent
No
This parameter specifies the code the Octel 50 system must
insert at the end of the dialing string to turn the Message
Waiting Light off.
This parameter is set when the Integrator utility is run, if
required by the switch.
Some switches require both a prefix code and a suffix code.
When Integrator is run, the Octel 50 system sets both
parameters, if required.
If Use Communications Message Waiting Light Software is
enabled, the Message Waiting Light Suffix OFF Code must
be left blank.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual value.
Not applicable.
Not applicable.
Requires
Restart
Dependent
No
This parameter determines whether the Octel 50 system
performs call progress for message waiting light requests to
the switch.
This parameter is set when the Integrator utility is run. Some
switches require the Octel 50 system to wait for a
confirmation tone to indicate the switch accepted the
message waiting light event before returning to the call.
This parameter should also be enabled for switches that do
not allow message waiting lights to be activated on busy
extensions.
None.
Not applicable.
Not applicable.
Requires
Restart
Dependent
No
Switch-
Set by
Integrator
Yes
Yes
Switch-
Set by
Integrator
Yes
Yes
Switch-
Set by
Integrator
Yes
Yes
8-66