Functional fault
Poor wrap-around
Back spraying
No wrap-around
Ventilstange undicht
PART NO. DOC2321362
Cause
• Poor earthing at object
• Paint resistance too high / too
low
• Spraying pressure too high
• Object not earthed
• Distance between spray gun
and object too large
• High voltage set wrongly (too
high)
• No high voltage
• Seal in end piece defective
• Air-passages damp
• Dichtungen der Ventilstange
beschädigt
AquaCoat GM 5000EACW
Remedy
• Check earthing of object or hanger with
ohmmeter
• Check resistance of paint
see chapter 4.1.1
• Readjust spraying pressure
• Check earthing
• Reduce distance between spray gun and
object
• Adapt high voltage to material
• Repair malfunction as laid down in the
control unit operating instructions
• Repair by Wagner Service Center
• Cleaning air-passages and drying
• Replace the seals (see chapter 8)