EDITION 04/2012
OPERATING MANUAL
5.4.11
SET AND SAVE RECIPES
Nominal values for the high voltage (kV) and for the spray current limiter (µA) are stored in
a recipe. As standard, the following values are saved in the factory in the 3 storage places
available for recipes:
Recipe No.
Target high voltage in kV
R1
R2
R3
Recipes 1-3 can be selected and saved directly using program buttons R1, R2 and R3. Once
the recipe required has been called up, the individual coating parameters can be called
up and changed using the corresponding selection buttons (see chapter 5.4.7 and 5.4.8).
When a parameter is changed, the LED on the left of the program button fl ashes to indicate
that a parameter value has been changed.
The process for saving parameters is described below.
To reuse the originally set values, press the program button briefly. The modifi ed values
●
are not taken over.
To save the modified values, press the appropriate program button and hold for
●
approx. 2 seconds until the LED beside the button flashes quickly. The modified values
are then saved.
PART NO. DOC2321362
Target spray current limiter in µA
70
60
40
AquaCoat GM 5000EACW
100
100
80
52