EDITION 04/2012
OPERATING MANUAL
5.5
DEVICE CONFIGURATION
5.5.1
OVERVIEW OF PARAMETERS
Parameters
C13 User lock
C19 Reset recipes
Reset
C20
confi guration
PART NO. DOC2321362
Value
Description
off
User lock is switched off.
(Factory setting)
User lock is switched on: no target values (kV and µA) can
on
be adjusted; you can only select the recipe and the control
functions.
User lock pro (program)
You can select recipes and control functions.
pro
The target values (kV and µA) can be adjusted but cannot
be saved in the recipes.
no
No reaction
(Factory setting)
All programs are set to delivery status when "res" is saved
res
by the maintenance key.
no
No reaction
(Factory setting))
All confi guration parameters are set to delivery status
res
(factory setting) when "res" is saved by the maintenance
key.
AquaCoat GM 5000EACW
60