Spraypack Examples With Double Diaphragm Pump Cobra - WAGNER AquaCoat AirCoat GM 5000EACW Operating Manual

Aquacoat aircoat-spray system for noncombustible spray media aquacoat aircoat - evomotion 20-30s - wildcat 18-40 - puma 28-40 - cobra 40-10
Table of Contents

Advertisement

EDITION 04/2012
OPERATING MANUAL
5.3.2.2

SPRAYPACK EXAMPLES WITH DOUBLE DIAPHRAGM PUMP COBRA 40-10

Check the unit for leaks:
1. Place container (13) with suitable detergent into the AquaCoat cabinet.
2. Immerse in container the suction system (12).
3. Connect the earth.
4. Connect the AquaCoat system to the compressed air source (8).
5. Set a maximum pressure of 0.6 MPa; 6 bar; 87 psi on the control unit of the Cobra 40-10.
6. Maintain the pressure for 5 minutes and check all connecting parts for leaks.
7. When the tightness of the system has been ascertained, release the spray gun (4).
8. Flush system through well.
9. Relieve system pressure and secure the spray gun (4).
10. Remove the detergent.