6.1

FINISHING WORK AND CLEANING

1. Switch off control unit.
2. Ensure that the material pressure is relieved and shut off the air supply to the gun.
3. Connect up the supply of cleaning solvent.
With round jet nozzle fi tted:
4. By means of nozzle spanner, loosen nozzle insert by a half turn.
5. Actuate the trigger guard. Flush the gun through thoroughly.
6. Relieve the pressure of gun and unit!
7. Re-tighten the nozzle insert.
8. Clean the spray gun body with a cleaning agent recommended by the manufacturer
and dry with a cloth or blow gun.
With fl at jet nozzle fi tted:
5. Remove AirCoat nozzle and clean separately (see chapter 5.4.7).
6. Actuate the trigger guard. Flush the gun through thoroughly.
7. Relieve the pressure of gun and unit!
8. Clean the spray gun body with a cleaning agent recommended by the manufacturer
and dry with a cloth or blow gun.
Cleaning agent in the air duct!
Functional faults caused by swollen seals
Discharge current to ground -> no high voltage
Always point the spray gun down when cleaning.
Ensure that neither paint nor cleaning agent enters the air duct.
When taking a break from work or when stored for a longer period, the spray gun
has to be positioned correctly with the attachment pointing downwards.