Faults are indicated by the "Fault" LED (24). In addition the error number is shown in the
display (27). If a fault occurs, the high voltage is switched off immediately. The user can only
continue to work once the fault has been remedied and acknowledged with push button
"service" 25).
Code
Malfunction
Display
E11
Earth monitoring
E12
No coil current/
Cascade interrupt
E13
Coil current too big
E21-E25 Exception error
PART NO. DOC2321362
24
25
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
μA
R3
Cause
The grounding cable is
●
interrupted
The gun is not connected
●
The cascade is not connected
●
Cascade is interrupted -->
●
defective
The cascade is defective
●
Hardware defect has occurred
●
AquaCoat GM 5000EACW
27
POWER
POWER
0
1
AquaCoat
B_03505
Remedy
Check/replace gun cable
●
Check or replace spray gun
●
Connect the spray gun
●
Connect the cascade
●
Check or replace cascade
●
Check or replace cascade
●
If problem persists,
●
contact Wagner Service Team
69