Starting Operation; General Rules For Making Adjustments To The Spray Gun - WAGNER AquaCoat AirCoat GM 5000EACW Operating Manual

Aquacoat aircoat-spray system for noncombustible spray media aquacoat aircoat - evomotion 20-30s - wildcat 18-40 - puma 28-40 - cobra 40-10
Table of Contents

Advertisement

EDITION 04/2012
OPERATING MANUAL
5.3

STARTING OPERATION

5.3.1

GENERAL RULES FOR MAKING ADJUSTMENTS TO THE SPRAY GUN

➞ Observe general safety instructions in chapter 2.
High voltage field!
Danger to life from malfunctioning heart pacemakers
Ensure that persons with heart pacemakers:
SIHI_0049_GB
Unintentional putting into operation!
Risk of injury
Before all work on the unit, in the event of work interruptions and
functional faults:
SIHI_0065_GB
Electrical discharge!
Risk of injury
➞ Maintain a safety distance of 100 mm; 4 inches from the nozzle
SIHI_0129_GB
Danger zone:
PART NO. DOC2321362
Do not work with the electrostatic spray gun.
Remain outside the area of the electrostatic spray gun/work -
piece.
WARNING
Switch off the energy/compressed air supply.
Relieve the pressure from the spray gun and unit.
Secure the spray gun against actuation.
By functional faults: Identify and correct the problem, proceed
as described in chap „Trouble shooting".
area of the spray gun during the spraying process and at least 20
seconds after the end of the spraying process.
A
A
A
A
A = 100 mm
A = 4 inch
AquaCoat GM 5000EACW
DANGER
CAUTION
Note
In order to avoid electrical discharges,
a distance of 100 mm; 4 inches must be
maintained from the work piece and
other earthed objects during the spray
process.
B_03526
: