Setting Example "Parameter C13 - WAGNER AquaCoat AirCoat GM 5000EACW Operating Manual

Aquacoat aircoat-spray system for noncombustible spray media aquacoat aircoat - evomotion 20-30s - wildcat 18-40 - puma 28-40 - cobra 40-10
Table of Contents

Advertisement

EDITION 04/2012
OPERATING MANUAL
For ease of operation the confi guration settings are divided into three groups. The fi rst
group is for the end user, the other both groups, protected by a password, are reserved for
Wagner Service and the Wagner production sites or the Wagner Service Center, which have
the necessary infrastructure.
Group 1:
Parameters C11 to C20
(end user)
Group 2:
Parameters C21 to C30
(Wagner service)
Group 3:
Parameters C31 to C40
(production plant, service center)
5.5.3

SETTING EXAMPLE "PARAMETER C13"

After getting started in confi guration mode, the display (27) shows the parameter "C11" by
default. You can change to parameter "C13" by pressing the "Spray current" (5) or the "High
voltage" (7) button.
To change a selected parameter value (e.g. C13), press Push key "standby" (25). The content
of the parameter is displayed in the LED display (27).
PART NO. DOC2321362
R1
R2
R3
25
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
μA
R3
7
5
3
AquaCoat GM 5000EACW
27
80
100
60
80
40
60
20
40
10
20
kV
μA
8
6
4
27
POWER
POWER
0
1
AquaCoat
B_03509
POWER
POWER
0
1
AquaCoat
B_03508
62

Advertisement

Table of Contents
loading

Table of Contents