DCN multimedia Release Notes 1.41
4.4.2

Preparing

Extract the docs.zip file to c:\inetpub\wwwroot.
(The file can be found on the DVD in the folder html\fileadmin\docs)
The documents are placed inside subfolders in the meetingdocuments folder.
Each meeting has its own subfolder; each meeting subfolder can have several agenda topics with
dedicated subfolders.
The following links can be added in the meeting application:
Hyperlink for a meeting:
http://«server ip-address»/default.aspx?meeting=«foldername of the meeting»
Hyperlink for an agenda topic:
http://«server ip-address»/default.aspx?meeting=«foldername of the meeting»&agenda=«foldername of the agenda topic»
The website contains a java-script, which ensures that the MMDs regularly update the list of
documents. This means that when a new document is placed in the subfolders it will be
automatically shown on the MMD (without any user interaction).
4.4.3

Troubleshooting

If HTTP ERROR 500.19 is shown in the web-browser you might have a double mime-type
definition. To solve this you can remove the mime-type definition in IIS or remove the mime-type
definition in the web.config file located in the folder of the web-site.
If the documents are not shown on the MMD, try to open the link in a web browser on the server
PC. If the documents are shown on the server PC, please check the firewall of the server.
4.5 How to downgrade from DCN multimedia version 1.2 to DCN
multimedia version 1.17
Install DCNmFirmware.msi from the Technician - Installer folder from the 1.17.5730
release
Start the Firmware Upload Tool (3.21.2712) and upload the DCNM-APS, DCNM-PS and
DCNM-MMDs with 1.17.5730 firmware
Manually de-install (through Control Panel - Programs and Features) the following
programs:
OMNEO ARNI Firmware (3.21)
o
DCN multimedia Firmware 1.17.5730
o
ARNI Configuration Tool (3.21)
o
OMNEO Firmware Upload Tool (3.21)
o
Bosch DNS-SD Service (3.21), this de-install signals for a reboot
o
Bosch DCN multimedia 1.20
o
Reboot the PC
Optionally clear the DcnmDataBase
Install DcnmSetup.exe from the Technician - Installer folder from the 1.17.5730 release
4.6 How to downgrade from DCN multimedia version 1.1 to DCN
multimedia version 1.0
During installation of DCN multimedia version 1.1 over DCN multimedia version 1.0 a backup with
filename DcnmBackup_v1.00.bak of the current database is made in the folder
%ProgramFiles%\Microsoft SQLServer\MSSQL10_50.SQLEXPRESS\MSSQL\DATA\DcnmBackup\
Most of the times
%ProgramFiles%
Downgrade instructions:
1. De-install DCN multimedia 1.1
a. Start programs and features via Windows Start - Control Panel
b. Select Bosch DCN multimedia version 1.1 and uninstall
c. Wait for the next step until the de-installation is finished
2. Delete the database
a. Download SQL Server management Studio 2008 R2 from
http://www.microsoft.com/en-us/download/details.aspx?id=22985
Bosch Security Systems| 2015-02-24
is the folder