SECTION 6 - TROUBLESHOOTING

Code 19 - Alarm - Disconnected

Check For These Obvious Conditions First:
• Damaged wiring in the alarm wiring harness or a damaged alarm.
• Activate a function to check if alarm beeps.
STEP
1.
Check voltage at the P1 connector on the Ground Control Module between
pin-13 and pin-6. Is reading within specification?
2.
Remove the wire terminals at the alarm, check continuity of each of the
wires from pins 13 and 6 on the P1 connector to the alarm end.

Code 20 - Beacon - Short Circuit

Check For These Obvious Conditions First:
• Damaged wiring in the beacon wiring harness or a damaged beacon unit.
STEP
1.
At the Ground Control Module, P1 connector, check the voltage across
pins-12 and 5 to the beacon. Is reading within specification?
2.
Remove the wire terminals at the beacon, check continuity of each of the
wires from pins 12 and 5 on the P1 connector to the beacon end.
6-26
Table 6-23. Code 19 - Alarm - Disconnected
ACTION
Table 6-24. Code 20 - Beacon - Short Circuit
ACTION
– JLG Lift –
SPEC
YES
2 - 4V DC
Replace Ground
Control Module
Replace the Alarm
SPEC
YES
0 - 2V DC
Go to Step 2
Replace the
Beacon
NO
Go to Step 2
Repair or
Replace Wiring
NO
Replace Ground
Control Module
Repair or
Replace Wiring
3121231