SECTION 6 - TROUBLESHOOTING
Code 04 - Tilt Condition
Check For These Obvious Conditions First:
• If machine is on a tilt of more than 1.5° in either or both the X or Y direction, this is normal operation.
(DRIVE and LIFT UP are disabled when tilt is detected)
• Check if Ground Control Module is mounted securely to the mast support column.
STEP
1.
Using a digital level check the actual level of the machines' resting surface in
both the X and the Y directions. Does surface check within machine specifi-
cation.
2.
At the Ground Control Module, enter the programming mode (See Ground
Control Programming, Section-3 of Service Manual) and check the tilt sen-
sor X and Y readings. Are readings within machine specification?
3.
Zero Tilt Sensor on a surface checked to within 0.0 degrees with a digital
level in both the X and Y directions. (See Ground Control Programming, Sec-
tion-3 of Service Manual).
NOTE: If frequent calibration of the internal Tilt Sensor is required, replace the Ground Control Module.
Code 05 - Reserved
6-20
Table 6-9. Code 04 - Tilt Condition
ACTION
– JLG Lift –
SPEC
YES
1.5°
Go to Step 2
X and Y Direction
1.5°
Replace Ground
X and Y Direction
Control Module
—
—
NO
Drive Machine to
Level Surface
Go to Step 3
—
3121231