SECTION 6 - TROUBLESHOOTING

Code 33 - Both PHP Bars - UP

STEP
1.
Perform steps in Code 2, Left PHP Bar UP then, Code 3, Right PHP Bar UP .
Do either of these steps correct the problem?
2.
Perform steps in Table 6-5 - Machine In Drive Speed Cut-Back (Turtle)
Mode All The Time, of this section.

Code 34 - P2-Auxiliary #1 - Inhibit

Check For These Obvious Conditions First:
• Platform Gates Closed.
• Pressure on the Platform Foot-switch (after power up).
NOTE: In the procedures below, if you check continuity between pin 6 and 16 it should show open circuit, when the platform
gates are closed and nothing is on the foot switch. When you step on the foot switch with the gates closed, you should
see a closed circuit.
STEP
1.
At the Ground Control Module, P2 connector, check the voltage across
pins-16 (orange/red 49-5) and 6 (black 12) is reading within specification?
2.
Remove the P2 connector from the Ground Station Module; check continu-
ity of the individual wires in the platform harness. (P2 to platform junction
box),
3.
Check continuity of gate switches and foot-switch circuit. (Switches are
wired in series; doors shut and foot switch depressed, circuit will be
closed)

Code 35 - P2-Auxiliary #1 - Tie Down

Check For These Obvious Conditions First:
• Pressure on the Platform Foot-switch during machine power up.
NOTE: In the procedures below, if you check continuity between pin 6 and 16 it should show open circuit, when the platform
gates are closed and nothing is on the foot-switch. When you step on the foot switch with the gates closed, you should
see a closed circuit.
STEP
1.
At the Ground Control Module, P2 connector, check the voltage across
pins-16 (orange/red 49-5) and 6 (black 12) is reading within specification?
2.
Remove the P2 connector from the Ground Station Module; check continu-
ity of the individual wires in the platform harness. (P2 to platform junction
box),
6-32
Table 6-35. Code 33 - Both PHP Bars - UP
ACTION
Table 6-36. Code 34 - P2-Auxiliary #1 - Inhibit
ACTION
Table 6-37. Code 35 - P2-Auxiliary #1 - Tie Down
ACTION
– JLG Lift –
SPEC
YES
Done
Done
SPEC
YES
0 - 2V DC
Go to Step 2
Go to Step 3
Consult Factory
SPEC
YES
0 - 2V DC
Go to Step 2
Go to Step 3
NO
Go to Step 2
Consult Factory
NO
Replace Ground
Control Module
Repair or
Replace Platform
Harness
Replace Compo-
nent or Repair
Wires
NO
Replace Ground
Control Module
Repair or
Replace Platform
Harness
3121231