Codes 41 thru 46 - OSS - Sensor 1 through 6 - Fault Condition

Check For These Obvious Conditions First:
• Is there an obstruction under the sensor showing the fault?
• Is the faulted sensor mounted properly and securely to the platform base frame?
Table 6-39. Codes 41 thru 46 - OSS - Sensor 1 through 6 - Fault Condition
STEP
1.
Is machine equipped with an OSS system?
2.
At the Ground Control Module, enter programming mode and view if OSS is
enabled. Is OSS enabled?
3.
In Service Level Programming mode, Disable Obstruction Senor System.
4.
Replace the sensor showing the fault. Does this correct the problem.
5.
Replace the complete OSS system, module and sensors.
3121231
ACTION
– JLG Lift –
SECTION 6 - TROUBLESHOOTING
SPEC
YES
Got to Step 4
X = No
Go to Step 3
X=No
Done
NO
Go to Step 2
Replace Ground
Control Module
Go to Step 4
Go to Step 5