SECTION 1 - MACHINE SPECIFICATIONS
Size
3
3.5
4
5
6
7
8
10
12
14
16
18
20
22
24
27
30
33
36
42
NOTES: 1. THESE TORQUE VALUES DO NOT APPLY TO CADMIUM PLATED FASTENERS
2. ALL TORQUE VALUES ARE STATIC TORQUE MEASURED PER STANDARD AUDIT
*3. ASSEMBLY USES HARDENED WASHER OR FASTENER IS PLACED AGAINST PLATED
4. CLAMP LOAD LISTED FOR SHCS IS SAME AS GRADE 8 OR CLASS 10.9 AND DOES NOT
1-10
Tensile
Clamp
(Dry or Loctite®
PITCH
Stress
Load
Area
Sq mm
KN
0.5
5.03
2.19
0.6
6.78
2.95
0.7
8.78
3.82
0.8
14.20
6.18
1
20.10
8.74
1
28.90
12.6
1.25
36.60
15.9
1.5
58.00
25.2
1.75
84.30
36.7
2
115
50.0
2
157
68.3
2.5
192
83.5
2.5
245
106.5
2.5
303
132.0
3
353
153.5
3
459
199.5
3.5
561
244.0
3.5
694
302.0
4
817
355.5
4.5
1120
487.0
METHODS TOLERANCE = ±10%
STEEL OR RAW ALUMINUM
REPRESENT FULL STRENGTH CAPABILITY OF SHCS. IF HIGHER LOAD IS REQUIRED,
ADDITIONAL TESTING IS REQUIRED.
Figure 1-5. Torque Chart (METRIC Fasteners - Sheet 5 of 7))
CLASS 8.8 METRIC BOLTS
CLASS 8 METRIC NUTS
Torque
Torque
Torque
(Loctite® 262
(Lub)
OR Vibra-
TM
263
)
TITE
[N.m]
[N.m]
[N.m]
1.3
1.0
2.1
1.6
3.1
2.3
6.2
4.6
11
7.9
18
13
26
19
50
38
88
66
140
105
219
164
301
226
426
320
581
436
737
553
1080
810
1460
1100
1320
1990
1490
1790
2560
1920
2300
4090
3070
3680
– JLG Lift –
Torque
(Loctite®
TM
TM
TM
242
or 271
OR Vibra-
TM
TM
131)
TITE
111 or
140)
[N.m]
1.2
1.4
1.9
2.3
2.8
3.4
5.6
6.8
9.4
12
16
19
23
28
45
55
79
97
126
154
197
241
271
331
383
469
523
639
663
811
970
1130
1530
2090
2690
4290
NO. 5000059 REV. J