SECTION 4 - CONTROL COMPONENTS
Table 4-1. MVL/MSP Ground Control Module - Field Programmable Settings and Factory Preset.
Level-2: Service Level Settings
Level-3: Operator Level Settings
LEVEL
2
Ancillary 1 Anti-Tie-down
2
Ancillary 2 Anti-Tie-down
2
Mode Select Delay (active before time-out)
2
Invert Lift Direction
2
Lift Lock Delay
2
Acceleration (platform lowered)
2
Deceleration (platform lowered)
2
Turn Acceleration (platform lowered)
2
Turn Deceleration (platform lowered)
2
Maximum Forward Speed (platform lowered)
2
Minimum Forward Speed (platform lowered)
2
Maximum Reverse Speed (platform lowered)
2
Minimum Reverse Speed (platform lowered)
2
Maximum Turn Speed (platform lowered)
2
Minimum Turn Speed (platform lowered)
2
Minimum Forward Speed (platform elevated)
2
Minimum Reverse Speed (platform elevated)
2
Minimum Turn Speed (platform elevated)
2
Motor Compensation
2
EPPROM Reset
Notes: (a) MSP Models equipped with stock-picker platform and mid-gate interlock (drive inhibit) switch are factory preset to HIGH.
(b) MSP Models equipped with 12 ft. or 14 ft. lift-limit-switch option are factory preset to HIGH.
4-16
PROGRAMMABLE ITEM
On LCD Display:
FACTORY PRESET
0
0
5 Sec.
NO
5 Sec.
80
80
50
50
100
40
50
20
20
15
13
13
5
50 mOhms
– JLG Lift –
YES =
HIGH =
NO =
LOW =
SETTING RANGE
0-1
0-1
0 - 60 Seconds
YES/NO
0 - 60 Seconds
1 - 100
1 - 100
1 - 100
1 - 100
1 - 100
1 - 100
1 - 100
1 - 100
1 - 100
1 - 100
1 - 100
1 - 100
1 - 100
0 - 500 mOhms
Resets GCM to default factory settings