Toshiba e-studio600 Service Manual page 94

Multifunctional digital systems
Hide thumbs Also See for e-studio600:
Table of Contents

Advertisement

Notes:
The digit after the hyphen in "Code" of the following table is a sub code.
In "RAM", the NVRAM or FRAM of the board in which the data of each code is stored is indi-
cated. "M" stands for the LGC board, "SYS" and "UTY" stands for the SYS board.
Classifi-
Code
cation
200
General
Date and time setting
201
General
Destination selection
202
User
Counter installed externally
interface
203
General
Line adjustment mode
204
User
Auto-clear timer setting
interface
205
User
Auto power save mode
interface
timer setting
e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
Setting mode (08)
Func-
Items
tion
ALL
ALL
ALL
ALL
ALL
ALL
2 - 70
Default
<Accept-
RAM
able
value>
-
-
Year/month/date/day/
<13 dig-
hour/minute/second
its>
Example:
03 07 0 13 13 27 48
"Day" - "0" is for
"Sunday". Pro-
ceeds Monday
through Saturday
from "1" to "6".
EUR: 0
M
0: EUR
UC: 1
1: UC
JPN: 2
2: JPN
<0-2>
0
M
0: No external counter
<0-3>
1: Coin controller
2: Copy key card
3: Key copy counter
0
M
0: For factory shipment
<0-1>
1: For line
*
Field: "0" must be
selected
3
SYS
Timer to return the
<0-10>
equipment to the
default settings when
the [START] button is
not pressed after the
function and the mode
are set
0: Not cleared
1 to 10: Set number x
15 sec.
11
SYS
Timer to automatically
<0, 6-15>
switch to the Auto
power save mode when
the equipment has not
been used
0: Invalid
7: 4min.
9: 7min.
10: 10min.
11: 15min.
12: 20min.
13: 30min.
14: 45min.
15: 60min.
Proce-
Contents
dure
5
1
1
1
1
1
6: 3min.
8: 5min.
March 2005 © TOSHIBA TEC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio720E-studio850E-studio520

Table of Contents