Classifi-
Code
cation
1824
Image
Exposure amount (laser
quality
power) upper limiter setting
control
1825
Image
Exposure amount (laser
quality
power) lower limiter setting
control
1826
Image
Image quality control auto-
quality
start setting
control
(When power is turned ON
first in a day)
1827
Image
Image quality control auto-
quality
start setting
control
(Specified number of
sheets for auto-start have
been printed from the start
of previous image quality
control)
1828
Image
Image quality control auto-
quality
start setting
control
(Specified period of time
for auto-start has passed)
1829
Image
Image quality control auto-
quality
start setting
control
(When recovered from
toner-empty status)
1830
Image
Image quality control auto-
quality
start setting
control
(Specified number of
sheets have been printed
from first image quality
control start in a day or
warming-up recovery)
March 2005 © TOSHIBA TEC
Setting mode (08)
Default
Func-
<Accept-
Items
tion
value>
ALL
Refer to
contents
<0-1500>
ALL
Refer to
contents
<0-1500>
ALL
ALL
ALL
ALL
ALL
e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 143
RAM
Contents
able
M
The upper limit of the
laser power control is
set.
[Unit: µW]
<Default value>
e-STUDIO520: 1020
e-STUDIO600: 1020
e-STUDIO720: 1020
e-STUDIO850: 610
M
The lower limit of the
laser power control is
set.
[Unit: µW]
<Default value>
e-STUDIO520: 600
e-STUDIO600: 600
e-STUDIO720: 600
e-STUDIO850: 270
0
M
0: Enabled
<0-1>
1: Disabled
0
M
0: Enabled
<0-1>
1: Disabled
0
M
0: Enabled
<0-1>
1: Disabled
0
M
0: Enabled
<0-1>
1: Disabled
0
M
0: Enabled
<0-1>
1: Disabled
Proce-
dure
1
2
1
1
1
1
1
1

Hide quick links: