Adjustment of the magnification ratio of the lens
Notes:
Perform this adjustment only when the lens unit is taken off or replaced.
Make sure that the primary scanning reproduction ratio (printer section) is correct before this
adjustment.
(1)
Place a ruler on the original glass (in the primary scanning direction) and make a copy on A4/LT-
sized paper at 100% reproduction ratio.
(2)
Compare the copied ruler with the actual
ruler.
(3)
If each mark on the rulers differs, perform the adjustment with the following procedures.
<Procedure>
(1)
Take off the original glass and lens cover.
(2)
Loosen 4 screws fixing the lens unit.
e-STUDIO520/600/720/850 ADJUSTMENT
Feeding Direction
Copied ruler
Screw
Lens unit
3 - 42
Actual ruler
Fig.3-35
Screw
Fig.3-36