Classifi-
Code
cation
410
Fuser
Fuser roller temperature
during printing
(Plain paper)
411
Fuser
Fuser roller temperature at
ready status
412
Fuser
Fuser roller temperature
during printing
(Thick paper 3)
413
Fuser
Fuser roller temperature
during printing
(Thick paper 1)
March 2005 © TOSHIBA TEC
Setting mode (08)
Default
Func-
<Accept-
Items
tion
value>
ALL
<0-14>
ALL
Refer to
contents
<0-14>
ALL
<0-14>
ALL
<0-14>
e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 91
RAM
Contents
able
12
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
<Default value>
e-STUDIO520
UC, EUR: 12
e-STUDIO600
JPN: 9
UC, EUR: 12
e-STUDIO720
JPN: 9
UC, EUR: 12
e-STUDIO850
JPN: 12
UC, EUR: 12
12
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
12
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
Proce-
dure
1
2
1
1
1