"Update Failed." is displayed at the bottom of the LCD screen when the updating is not com-
pleted properly. Turn OFF the power, and then check the following items. After confirming and
clearing the problems, restart updating from the beginning.
•
Is the download jig connected properly?
•
Is the updating data written to the download jig properly?
•
Do the download jig and the equipment operate properly?
(7)
Turn OFF the power, and then remove the download jig.
(8)
Perform the "Updating System ROM" continuously.
P.6-10 "6.1.2 PWA-DWNLD-350-JIG2 (48 MB) <System ROM / Engine ROM / Scanner ROM
/ Laser ROM / PFC ROM>" <Updating System ROM>
[B]
Confirmation of the updated data
After the updating is completed, check each data version in the Setting Mode (08) to confirm that the
data was overwritten properly.
08-900: System ROM version
08-920: FROM basic section software version
08-921: FROM internal program version
08-922: UI data fixed section version
08-923: UI data common section version
08-924: Version of UI data language 1 in HDD
08-925: Version of UI data language 2 in HDD
08-926: Version of UI data language 3 in HDD
08-927: Version of UI data language 4 in HDD
08-928: Version of UI data language 5 in HDD
08-929: Version of UI data language 6 in HDD
08-931: Version of UI data language 7 in HDD
08-930: Version of UI data in FROM displayed at power ON
08-933: HDD unit data version
08-934: Version of Web UI data language 1 in HDD
08-935: Version of Web UI data language 2 in HDD
08-936: Version of Web UI data language 3 in HDD
08-937: Version of Web UI data language 4 in HDD
08-938: Version of Web UI data language 5 in HDD
08-939: Version of Web UI data language 6 in HDD
e-STUDIO520/600/720/850 FIRMWARE UPDATING
Fig.6-7
6 - 6