(8)
"Update Completed." is displayed at the bottom of the LCD screen after the updating is com-
pleted properly.
"Update Failed." is displayed at the bottom of the LCD screen when the updating is not com-
pleted properly. "Failed" appears next to the failed item on the status display.
Is the download jig connected properly?
Is the updating data written to the download jig properly?
Do the download jig and the equipment operate properly?
(9)
Turn OFF the power, remove the download jig and install the cover plate.
(10) Perform the initialization of the updating data.
Turn ON the power while [0] button and [8] button are pressed simultaneously.
Key in "947", and then press the [START] button.
Press the [INITIALIZE] button.