Toshiba e-studio600 Service Manual page 136

Multifunctional digital systems
Hide thumbs Also See for e-studio600:
Table of Contents

Advertisement

Classifi-
Code
cation
841
Transfer
Transfer timing correction
844
Fuser
Switching timing into low-
speed pre-running from
start of ready status
(Pressure roller)
e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
Setting mode (08)
Func-
Items
tion
ALL
ALL
2 - 112
Default
<Accept-
RAM
able
value>
1
M
The timing to turn on
<0-14>
the transfer bias is cor-
rected.
<e-STUDIO600/
e-STUDIO720>
0: Approx. 1.4 mm
passed from the ref-
erence position
1: Turns on at the ref-
erence position
(default)
2: Approx. 1.4 mm
before the reference
position
3: Approx. 2.8 mm
before the reference
position
4: Approx. 7.1 mm
before the reference
position
<e-STUDIO850>
0: Approx. 1.6 mm
passed from the ref-
erence position
1: Turns on at the ref-
erence position
(default)
2: Approx. 1.6 mm
before the reference
position
3: Approx. 3.3 mm
before the reference
position
4: Approx. 8.2 mm
before the reference
position
1
M
0: Switching disabled
<0-12>
1: 5 min.
2: 10 min.
3: 20 min.
4: 30 min.
5: 40 min.
6: 50 min.
7: 60 min.
8: 70 min.
9: 80 min.
10: 90 min.
11: 100 min.
12: 120 min.
<Default value>
e-STUDIO520
UC, EUR: 10
e-STUDIO600
JPN: 6
e-STUDIO720
JPN: 6
e-STUDIO850
JPN: 10
Proce-
Contents
dure
1
1
UC, EUR: 10
UC, EUR: 10
UC, EUR: 10
March 2005 © TOSHIBA TEC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio720E-studio850E-studio520

Table of Contents