(3)
Apply white grease (Molykote X5-6020) to
the places shown below.
Motor shaft (arrow A) :
About 3 small drops
E-rings (arrow B ; 2 places) :
About 2 small drops
* Apply to the surface contacting the
pulleys.
* 22.
Discharge LED
Clean with soft pads or cloth. Do not use a vacuum cleaner.
* 23.
Exit roller
Remove the pin from the exit roller (upper), and then apply a few drops of silicon oil over
the hole of the exit roller.
* 24.
Exit roller drive gear
Apply 1 rice-grain amount of white grease (Molykote X5-6020) on the shaft section where
the drive gear is installed.
* 25.
Separation roller (bypass feed unit)
Apply an even coat of grease (Alvania No.2) to all round the inside of the spring.
* 26.
Paper dust removal brush
Clean the frame if needed because paper dust brushed off with the corresponding brush
accumulates on the lower frame of the registration rollers.
(Cleaning period guideline: Every two or three times of Preventive Maintenance.)