Toshiba e-studio600 Service Manual page 419

Multifunctional digital systems
Hide thumbs Also See for e-studio600:
Table of Contents

Advertisement

NO Æ
È
YES
Does the voltage between J11-6 and -7 on the finisher controller PC board become 24V
when the swing motor starts rotating?
NO Æ
È
YES
Is the wiring between the swing motor and finisher controller PC board correct?
YES Æ Correct the wiring.
È
NO
Replace the swing motor.
[CC50] Horizontal registration motor abnormality
Is the horizontal registration home position sensor (PI1P) working normally?
NO Æ
È
YES
Is the wiring between the finisher controller PC board and horizontal registration home posi-
tion sensor (PI1P) correct?
NO Æ
È
YES
Is there any problem with the horizontal registration mechanism?
YES Æ Fix the mechanism.
È
NO
Is the problem solved by replacing the horizontal registration motor (M2P)?
YES Æ END
È
NO
Is the problem solved by replacing the punch motor?
YES Æ END
È
NO
Replace the finisher controller PC board.
March 2005 © TOSHIBA TEC
Replace the sensor.
Replace the finisher controller PC board.
Replace the sensor.
Correct the wiring.
5 - 91
e-STUDIO520/600/720/850 TROUBLESHOOTING
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio720E-studio850E-studio520

Table of Contents