ANGLE SENSOR

1 of 1
Check the engine idle speed and adjust it if neces-
sary
(page 3-15).
Adjust the TP sensor position so that the resistance
between terminals A and B is 580 620 Ω, and
tighten the shear bolts until the bolt heads break off.
Connect the TP sensor connector.
Perform the initial setting procedure
(page 24-6).
Install the removed parts in the reverse order of
removal.
INSPECTION
SENSOR RESISTANCE
Turn the ignition switch OFF.
Disconnect the angle sensor 3P connector.
Measure the resistance at the angle sensor 3P con-
nector.
Connection: Black/red (+) Green/yellow ()
Standard: 1.6 2.4 kΩ (20°C/68°F)
Clean around the sensor base with compressed air
before removing the angle sensor.
Remove the two socket bolts and angle sensor/
bracket assembly.
Check that the resistance at the angle sensor termi-
nal varies while turning the sensor joint.
The resistance should change smoothly as follows.
Connection: Yellow/blue (+) Green/yellow ()
Standard: 0 to 1.6 2.4 kΩ (20°C/60°F)
http://services.honda.com/ServiceManual/SVC_MNL/61HN253/61HN2...
TP SENSOR
A (Yellow/Black)
ANGLE SENSOR
BOLTS
G/Y
Y/Bu
HONDAMATIC
SHEAR BOLTS
B (Green/Yellow)
ANGLE SENSOR
JOINT
24-41
3/9/2008 11:31 PM