Table of Contents

Advertisement

'61HN252' by American Honda Motor Co. - Page 106 of 540
[2005-2008] [TRX500 FA/FGA]
LUBRICATION SYSTEM

OIL PUMP

4-12
1 of 1
Remove the bolt and oil strainer screen for the main
scavenge pump.
Clean the oil strainer and screen thoroughly.
Install the oil strainer screen and tighten the bolt
securely.
Coat a new O-ring with oil and install it onto the oil
strainer.
Install the oil strainer and tighten the bolt securely.
REMOVAL
Separate the crankcases
(page 13-8).
Remove the five bolts (gold) and oil pump from the
front crankcase.
http://services.honda.com/ServiceManual/SVC_MNL/61HN253/61HN2...
BOLT
OIL STRAINER SCREEN
(MAIN SCAVENGE)
OIL STRAINER SCREEN
(MAIN SCAVENGE)
OIL PUMP
O-RING
BOLTS
3/9/2008 10:43 PM