Network and Power Connection

2.7.6 Camera Startup Sequence

As soon as the power supply has been established, LEDs 1 and 2 will show the progress
of the startup sequence.
R
• Booting: Immediately after connecting the power supply, the red LED lights up, blinks
for two seconds, then stays on permanently red. A camera self-test is carried out at
this point, and the entire system is started. In case of an error, the camera will start
using the backup operating system.
• Waiting for key pressed: Both LEDs light up for four seconds. If you press the R or L
key of the camera during this time, the camera will execute the corresponding func-
tion (see Section 3.2.6, «Starting the Camera with an Automatic IP Address (DHCP)»
or Section 3.2.5, «Starting the Camera with the Factory IP Address» , respectively). To
paper clip
do so, use a
• Ready: Once the camera software has been started, the green LED is on permanently
and the red LED blinks. The camera can now be accessed via the network (browser,
MxControlCenter, MxEasy, MOBOTIX App, etc.).
During the startup sequence of the camera, the LEDs will always light up, even if they
have been deactivated in Admin Menu > LED Setup.
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • sales@mobotix.com
1
2
avoid using sharp or pointed objects!
but
Note
LED default settings:
1
2
L
1. Start
2. Key
3. Ready
91