6.12 Adding a WAN3 Module
This module is supplied with a LAN interconnect cable and a
for the power supply unit, and
Installation Requirements
Installation space either on or under the existing IP Office control unit.
•
Switched power outlet socket.
•
System password.
•
Free LAN port on the front of the control unit.
•
Grounding Requirements
•
Functional Ground - Connection of a
•
Tools Required
Manager PC.
•
DHCP server (preferably the IP Office itself).
•
Tools for rack mounting (optional).
•
Parts and Equipment Required
WAN3 10/100 Module
•
Each module is supplied with a suitable external power supply unit and a RJ45-RJ45 LAN interconnect cable.
For the IP412 control unit an RJ45-RJ45 LAN crossover cable is required.
•
WAN Cables
•
A V.24, V.35 or X.21 WAN cable is required for connection to each WAN port. The cable used determines the
signalling provided by that port.
Power cord for the power supply
•
Rack mounting kit
•
Cable labeling tags.
•
IP Office Installation
IP Office
cables
for the WAN ports on the rear of the module must be ordered separately.
functional ground
unit.
(optional).
IP400 Basic Installation: Adding Expansion Modules
WAN3 expansion modules connect to the IP Office control unit
using a LAN cable. It is preferred that the cable is connected
directly to the IP Office control unit rather than via any other
equipment. A green 1 meter (3'3'') LAN interconnect cable is
supplied with the module for this purpose though a replacement
cross-over cable is required if connecting to an IP412 control
unit.
The WAN3 module requires its own IP address on the same
subnet as the IP Office control unit. A WAN3 module obtains
that address using DHCP so a DHCP server is required for
installation.
power supply
unit. An appropriate
is recommend for all modules.
locale specific power cord
15-601042 Issue 20b (16 July 2009)
Page 129