5.18 Wall Mounting

IP Office Installation
IP Office
The IP500 control unit can be wall mounted. This requires an IP500 Wall
Mounting Kit (SAP 700430150) plus additional 4.5mm fixtures and
fittings suitable for the wall type. The wall mounting kit includes two
brackets, one top and one bottom.
Environmental Requirements
In addition to the existing
system, the following additional requirements apply when wall mounting
a unit:
The wall surface must be vertical, flat and vibration free.
A minimum clearance of 500mm (19.7 inches) is required on
all sides.
The unit must be orientated as shown when mounted. That is
with the base card slots facing right when viewed from in front of
the unit.
The brackets must be used as shown, with the deeper tray-
like bracket used at the bottom of the wall mounted control unit.
Only the screws (M3 x 6mm) provided with the mounting kit
should used to attach the brackets to the control unit.
IP500 Basic Installation: Rack Mounting
environmental requirements
15-601042 Issue 20b (16 July 2009)
for an IP Office
Page 101