Wan Cable - Avaya IP Office Installation Manual

Ip office installation
Hide thumbs Also See for IP Office:
Table of Contents

Advertisement

10.12.18 X.21 WAN Cable
This cable is used for connection from an IP Office 37-way D-type WAN port to the X.21 service providers equipment.
IP Office
WAN Port
1
20
4
23
24
5
2
21
3
22
6
• At the IP Office end pin 7 is connected to pin 6.
• At the IP Office end pin 19 is connected to the Screened Cable Drain
• Supply: This cable is not supplied with the control unit or WAN3 module. It must be ordered separately.
• SAP Code: 700213408.
• Cable: 6 twisted pair screened cable - each core is 7/0.203mm (24 AWG) tinned copper stranded wire, nominal
capacitance of 98pF/m, impedance of 77ohms at 1MHz, screened with aluminized tape and a tinned copper wire drain.
• Maximum Length: 5m/16'5''. This is the maximum length that should be used if the above cable is replaced with an
alternate cable.
IP Office Installation
IP Office
Signal
Rx-B: Receive B.
Rx-A: Receive A.
Tx-A: Transmit A.
Tx-B: transmit B.
Ctl-A: Control A.
Ctl-B: Control B.
Ind-A: Indicate A.
Ind-B: Indicate B.
Clk-A: Clock A.
Clk-B: Clock B.
Ground
Wire.
Wires
X.21 WAN
Service
Twisted Pair
11
4
Twisted Pair
2
9
Twisted Pair
3
10
Twisted Pair
5
12
Twisted Pair
6
13
------
8
15-601042 Issue 20b (16 July 2009)